Once a span exceeds 100 meters, choosing the wrong structural system can affect everything from steel consumption and foundation design to lifting operations and project schedules. These decisions can be difficult and costly to reverse.
This article explains three key aspects of large-span steel structure selection: which structural system suits different site conditions, how steel consumption varies with span, and how construction methods differ.
To develop a suitable solution for your project, simply provide the following information: project layout dimensions, required storage capacity, stacker-reclaimer model, and local snow load. Contact ZM-Besta for a project-specific steel structure solution.
Email: info@xzbesta.com
Many people start by asking which structural system is suitable for a 100-meter span. This is actually the wrong question. Even with the same 100-meter span, a circular stockyard and a long rectangular storage yard require different structural solutions.
A stacker-reclaimer rotates around a central point, and the storage area is circular. A spherical dome is a doubly curved structure that transfers loads to the perimeter ring beam in two directions. No internal columns are required, and the dome profile also follows the shape of the stored bulk material.
Air-supported membrane structures are another option for circular stockyards. The main differences lie in their maximum applicable span and fire protection requirements. Our article, Dome Storage Selection and Project Delivery: What You Need to Know, provides a more detailed explanation.
For a stockyard that is several hundred meters long and approximately 100 meters wide, a spherical dome is not a practical solution. Its diameter is insufficient, and its curved surface cannot extend continuously along the entire length.
A cylindrical shell has a singly curved surface that extends continuously along the longitudinal direction. Space frame end walls are used to enclose the ends, and projects exceeding 700 meters in length have been completed.
This type of large-span space frame building has become a mainstream enclosed storage solution in China’s coal, power, and cement industries.
When the area beneath a structure must remain accessible, existing railways, roads, belt conveyors, or factory buildings cannot be removed. The structure must therefore span over these obstacles.
Such projects are often asymmetrical: one support is located on an existing structure, while the other rests on a newly constructed foundation.
Prestressed tubular trusses can be designed with asymmetrical quadrilateral cross-sections. Balancing cables help adjust the bending moment, while spherical hinge supports allow rotational movement.
For structures crossing conveyor routes, the space frame conveyor trestle system must be designed with the main structure’s connection interfaces from the outset. Otherwise, the support reactions may not match the design requirements.

In a planar steel truss, members work primarily within a single plane, and additional bracing is required to provide out-of-plane stiffness. As the span increases, the bracing system needed to maintain stability becomes more substantial, driving up steel consumption.
A spatial space frame works as a three-dimensional load-bearing system. When a node is subjected to a load, forces are distributed in multiple directions through the surrounding diagonal and horizontal members. As a result, individual members can be smaller.
This structural mechanism is systematically discussed in the literature of the International Association for Shell and Spatial Structures (IASS).
| Span Range | Structural System | Reference Steel Consumption | Description |
| 15–50 m | Portal Frame | 25–60 kg/m² | Economical for small and medium-sized warehouses |
| 30–80 m | Planar Steel Truss | 40–90 kg/m² | Requires additional out-of-plane bracing |
| Over 60 m | Spatial Grid Shell / Space Frame | 30–60 kg/m² | Can use approximately 50% less steel than a planar truss at the same span |
| Over 100 m | Planar Steel Truss | Over 120 kg/m² | Conventional solid-web portal frames are no longer practical |
| Over 100 m | Traditional Space Frame Dome | Close to 120 kg/m² | Steel consumption can be significantly reduced through optimized grids and connections |
At around 60 meters, spatial structures begin to offer advantages. Below this span, portal frames and planar trusses can remain cost-competitive thanks to established production processes and relatively low fabrication costs.
At around 100 meters, planar structures begin to face significant challenges. The additional steel required to achieve out-of-plane stability can make planar trusses considerably less economical.
The figures above are reference ranges, not quotations. Snow loads, lateral pressure from stored materials, openings, and corrosion protection requirements can all change the final result. Steel consumption can vary by 30% or more between projects with the same span.

First, the initial ring is assembled in sections at ground level. Each section is then lifted into position and connected to form a closed, stable ring.
This initial ring serves as the supporting platform for subsequent installation. The space frame is assembled upward, with each completed section forming part of the load-bearing system for the structure above. This eliminates the need for full-height scaffolding.
The circular accuracy and elevation of the initial ring are critical, as any deviations can accumulate during the installation of subsequent rings.
A cylindrical shell can be installed starting from the gable end or by using a single-side arch lifting method.
First, a narrow starter section is assembled to form a stable structural unit. The structure is then extended toward the opposite side, with the remaining sections completed through high-level assembly.
The main challenge is ensuring the stability of the starter section itself. For a starter section spanning 118 meters and weighing 160 tonnes, controlling deformation during lifting requires much stricter measures than conventional installation work.

A single prestressed tubular truss can be extremely heavy, making it difficult to lift with conventional equipment.
The typical solution is to establish an assembly platform on one side of the site. Each truss is assembled section by section and then progressively pushed into position along temporary launching beams and tracks.
The critical operation is the support transfer. During the transition from the temporary launching system to the permanent supports, the structure must remain continuously supported without unloading. If the transfer sequence is incorrect, internal forces will redistribute.
| Construction Method | Applicable Structural Systems | Main Equipment | Key Control Challenges |
| High-Level Assembly | Spherical Domes and Cylindrical Shells | Small and medium-sized cranes | Initial ring circularity and cumulative installation errors |
| Single-Side Arch Lifting | Cylindrical Shells | Medium-sized cranes | Deformation control of the starter section |
| Incremental Launching | Prestressed Tubular Trusses | Assembly platforms and launching beams | Support transfer without unloading |

A 20% difference in steel consumption can mean dozens of tonnes of additional steel in a project involving hundreds of tonnes of structural steel.
Foundation requirements can differ even more significantly. Planar steel trusses typically transfer concentrated reactions through their supports, requiring thicker isolated foundations. Spatial space frames distribute support reactions more evenly, potentially allowing thinner foundations.
This difference becomes even more significant on soft soil foundations.
High-level assembly relies heavily on manual work and small lifting equipment, making it more vulnerable to weather conditions.
Incremental launching requires more extensive preparation at the early stage, but the actual launching operation can be completed quickly.
If the structural system does not match the site’s lifting capacity and construction conditions, delays can occur, with equipment waiting for the work area and the work area waiting for structural components.
Cylindrical shells are relatively easy to extend longitudinally. In many cases, an additional space frame section can simply be added.
Expanding a spherical dome’s diameter, however, generally requires substantial reconstruction.
If rooftop solar PV is planned, the additional loads should be considered during the initial structural design stage. Installing solar panels later can change the load distribution within the space frame.
Our article, The Cost per Tonne of Converting an Open Stockyard into an Enclosed Coal Storage Dome, examines the overall investment involved in enclosed stockyard conversion. Structural reserve capacity is one of the key variables.
| Project | Structural System | Span / Dimensions | Construction Method | Project Achievement |
| Xinjiang Tianchi Energy Circular Stockyards | Bolted Spherical Node Space Frame with a Regular Four-Pyramid Dome Configuration | 130 m diameter, 3 units | Initial ring assembly, sectional closure, and high-level assembly | 2020 Coal Industry Quality Engineering Award |
| Lianyungang Coal Supply Chain Base | Bolted Spherical Node Space Frame with a Regular Four-Pyramid Cylindrical Shell Configuration | 118 m × 736 m, 86,848 m² | Gable-end starting installation and single-side arch lifting | 2021 Shanghai Golden Steel Award for Construction Metal Structures |
| Guohua Xuzhou Power Plant Coal Yard Enclosure | Prestressed Tubular Truss | 185 m × 254 m, approximately 46,990 m² | Incremental launching and support transfer without unloading | China Installation Engineering Quality Award (China Installation Star) |
The Lianyungang project used a starter section 10 meters wide, with a span of 118 meters and a total weight of approximately 160 tonnes. It set a record in China for the single-side arch lifting method used in large-span, high-steel-consumption space frame construction. The project cost was approximately USD 16.9 million.
The Guohua Xuzhou Power Plant project consisted of 9 main trusses and 15 secondary trusses, with the heaviest single truss weighing 300 tonnes. For more project records, see ZM-Besta’s Overview of Large-Span Structural Engineering Capabilities.
It depends on the plan shape. For circular stockyards, a dome is generally more economical. For long rectangular stockyards, using multiple interconnected domes would complicate the joints and gutters, making a cylindrical shell more suitable. Comparing only the price per tonne of steel can lead to the wrong conclusion.
No. A space frame is a statically indeterminate structural system that distributes loads in multiple directions. Its structural redundancy under seismic loads can be higher than that of a planar rigid frame. Seismic design must comply with the applicable codes and standards for the project location, such as China’s GB 50011, Europe’s EN 1998, and the United States’ ASCE 7.
Bolted spherical nodes are suitable for projects requiring a high degree of standardization, export, and on-site assembly. They eliminate the need for on-site welding and reduce dependence on specialized welding skills. Welded spherical nodes offer higher load-bearing capacity in certain applications, but require more on-site welding, qualified welding procedures, and certified welders.
Steel expands and contracts with temperature changes. Under direct sunlight, large-span steel structures heat up and their members expand. The cumulative dimensional deviation at the closure point can reach several tens of millimeters. For this reason, closure operations are generally scheduled for nighttime or early morning, when temperatures are more stable.